產品介紹
70W AC Plug Changeable 插頭可換式
Interchangeable AC Plug 70Watts 5V~48V series, meet Energy Star Level: DoE VI / RoHS / Reach
Switching Adapter Interchangeable AC Plug
Safety
Regulatory Standard
The power supply shall complied the following international regulatory standards
Certified Country Certified Status Standard
UL USA ★ UL 60950-1、UL 62368-1
FCC USA ★ FCC PART 15
CE EUROPE ★ CE MARK、EN55032
TUV EUROPE ★ EN60950-1;2006+A2
PSE JAPAN ★ J60950-1(H27)、J55022(H22)
RCM AUSTRALIA ★ AS/NZS 60950-1:2011
BSMI TAIWAN ★ CNS13438
CCC CHINA ★ GB4943.1-2011
2.General Description
This specification defines the engineering features, functions, general design and performance requirements for a 60 watts switching mode AC to DC power supply.3.Electrical Specification
- InputRequirements
- InputVoltage
3.1.2Input LineFrequency
Operation Range:50 -60Hz Designing Range:47 – 63Hz3.1.3InputCurrent
The maximum input current is measured at Full load 1.5 A with 230Vac voltageconditions.3.1.4InrushCurrent
120A Max. less under 230Vac conditions. Interruption of the input voltage for duration sufficient to cause the output voltage to drop below the regulation setting shall cause reactivation of in rush limiting capability. Full-load 25 ℃ cold start.3.1.5Power Consumption
The power supply consumption less than 0.15 watt at rated 115/230 VAC input Voltage conditions.3.1.6Efficiency
It should provide an average efficiency of 83.0% minimum, when measured at (25%,50%,75%,100%) load under 115/230VAC(60/50Hz)and burn-in 30minutes.3.2OutputRequirements
- Output RatingVoltage
DC OUTPUT VOLTAGE | LOAD ( A ) | |||
Symbol Vo | Voltage | Regulation | Minimum | Maximum |
V+ | 15 V | 13.95 -16.05V | 0 A | 4.0A |
- Regulation
2.1.2Ripple &Noise
Output | Voltage | Load | Maximum Ripple & Noise |
1 | 15 V | Full Load | 250 mV (115/230Vac) |
- Measured at output terminal, added with a Low ESR Electrolytic capacitor of 47uF and 0.1uF ceramic capacitor to simulate system loading.
- Ripple and noise are defined as periodic or random signals over frequency bandof
2.1.3Turn-OnTime
The power supply shall turn on in less than 4 seconds with full load and 115Vac/60Hz input voltage conditions.2.1.4Hold-Up Time
Hold up time for the output must be at least 16 mS minimum with full load and 115Vac/60Hz input voltage conditions.2.1.5RiseTime
Rise time in less than 50 mS with 10% to 90% load 115Vac/60Hz input voltage conditions.2.1.6Transientresponse
The power supply output voltage shall not undershoot not or overshoot beyond the specified limits shown after applying load changes with a 0.15A/µsec slew rate on the output. Change Frequency to 100Hz and 1KHz with a 50% duty cycle.Voltage Limits | Load change | |
14.50Vdc | 16.70Vdc | 50% to 100% load and 100% back 50% |
2.2ProtectionCircuit
- Over Current Protection(OCP)
2.1.1 Over Voltage Protection(OVP)
The power supply shall operate in shut down mode at over voltage protection 130% maximum rating voltage , and it shall auto-recover if the fault is removed.2.1.2 Short Circuit Protection(SCP)
The power supply shall be protected from damage of accidentally short on the output terminal, and it shall auto-recover if the fault is removed.3. Reliability
3.1 MTBF(Mean-time-between-failures)Calculation
The demonstrated MTBF shall be more than 50,000 hours of continuous operation at 25℃, maximum load and using the MIL-HDBK-217F method.
4. RegulatoryStandard
4.1 EMCSpecification
POWER SUPPLY SPECIFIC EMC TEST REQUIREMENTS
EMC | Standard | Test CRITERIA (Method) | |
Electrostatic Discharge (ESD) |
EN 55024:2010, EN 61000-4-2 |
Air Discharge ±8kV | Contact Discharge ±4kV |
Radiated Field Immunity(RS) |
EN 55024:2010, EN 61000-4-3 |
Radiated Susceptibility 3V/m | |
Fast Transient Immunity(EFT) |
EN 55024:2010, EN 61000-4-4 |
Power line 1kV | Signal line 0.5kV |
Surge Immunity(Surge) |
EN 55024:2010, EN 61000-4-5 |
Common mode ±2kV | Differential mode ±1kV |
4.2 Radiated and ConductedEmission
Power supply shall with the radiated and conducted emission requirements for EN55032 Class B,FCC part 15B.2.Safety
- RegulatoryStandard
Certified | Country | Certified Status | Standard |
UL | USA | ★ | UL 60950-1、UL 62368-1 |
FCC | USA | ★ | FCC PART 15 |
CE | EUROPE | ★ | CE MARK、EN55032 |
TUV | EUROPE | ★ | EN60950-1;2006+A2 |
PSE | JAPAN | ★ | J60950-1(H27)、J55022(H22) |
RCM | AUSTRALIA | ★ | AS/NZS 60950-1:2011 |
BSMI | TAIWAN | ★ | CNS13438 |
CCC | CHINA | ★ | GB4943.1-2011 |
2.2Hi-pot
Dielectric Withstand Voltage, Primary(input AC short)-to-Secondary(output DC short): 3000Vac(4242Vdc),10mA, 1 minute(Production test for 3 second).2.3Leakage current
The AC leakage current to output is less than 3.5mA when the power supply is connected to 230VAC/50Hz.3.Environment
- Temperature andHumidity
Condition | Operation | Shipping / Storage |
Temperature | 0℃ ~ 40℃ | -20℃ ~ 70℃ |
Relative Humidity | 20% ~ 90% | 20% ~ 90% |
- Altitude
4.Mechanical
- Dimension andConfiguration
Weight | 450g ±20g | Input pin | Interchangeable Wall mount UK plug |
Dimensions | 122.73*52.14*42.6mm | Output connector | Skinned tinned |
Unit color | BLACK | Polarity | 180° White wire"+" ,Black wire “-“ |
Plastic | 94V-0 | Cable | NOUL2464 18AWG/2C 80℃ 300V L:4.0M |
EMI core | NA |